Operating altitude : 150 to 4,000m nominal
Horizontal accuracy : 1/5,500 x altitude; 1-sigma
Range capture : Up to 4 range measurements for each pulse, including last
Intensity capture : 12-bit dynamic range for each mesurement
Scan frequency : Variable 70 Hz, Optional 100 Hz
Scan angle : Variable from 0 to +/- 25º, in increments of +/- 1º
Scanner product : Scan angle x scan frequance < 1000
Roll compensation : 5 Hz Update rate,
(scan angle + roll comp angle = 30º)
(+/- 20º scan allows +/- 10º compensation)
|
 |
Laser rep rate (kHz) |
500m altitude |
1000m altitude |
2000m altitude |
3000m altitude |
4000m altitude |
33
50
70
100 |
<5 cm
<5 cm
<5 cm
<10 cm |
<10 cm
<10 cm
<10 cm
<10 cm |
<15 cm
<15cm
<15 cm
<15 cm |
<20 cm
<20 cm
N/A
N/A |
<25 cm
N/A
N/A
N/A |
|
 |
1/3 |
 |
|